Product Details
Place of Origin: China
Brand Name: ENNENG
Certification: CE,UL
Model Number: PMM
Payment & Shipping Terms
Minimum Order Quantity: 1 set
Price: USD 500-5000/set
Packaging Details: seaworthy packing
Delivery Time: 15-120 days
Payment Terms: L/C, T/T
Supply Ability: 20000 sets/year
Name: |
Interior Permanent Magnet Motor |
Current: |
AC |
Material: |
Rare Earth NdFeB |
Power Range: |
5.5-3000kw |
Installation: |
IMB3 IMB5 IMB35 |
Insulation Class: |
F(H) |
Cooling Way: |
IC411 Or IC416 |
Color: |
Blue, Grey, Etc. |
Name: |
Interior Permanent Magnet Motor |
Current: |
AC |
Material: |
Rare Earth NdFeB |
Power Range: |
5.5-3000kw |
Installation: |
IMB3 IMB5 IMB35 |
Insulation Class: |
F(H) |
Cooling Way: |
IC411 Or IC416 |
Color: |
Blue, Grey, Etc. |
Low Speed Three Phase 160kw 3600rpm Interior Permanent Magnet Motor
Analysis of the principle of the technical advantages of permanent magnet motor
The principle of a permanent magnet synchronous motor is as follows: In the motor's stator winding into the three-phase current, after the pass-in current, it will form a rotating magnetic field for the motor's stator winding. Because the rotor is installed with the permanent magnet, the permanent magnet's magnetic pole is fixed, according to the principle of magnetic poles of the same phase attracting different repulsion, the rotating magnetic field generated in the stator will drive the rotor to rotate, The rotation speed of the rotor is equal to the speed of the rotating pole produced in the stator.
Differences Between The Permanent Magnet Motor And Asynchronous Motor:
01. Rotor Structure
Asynchronous motor: The rotor consists of an iron core and a winding, mainly squirrel-cage and wire-wound rotors. A squirrel-cage rotor is cast with aluminum bars. The magnetic field of the aluminum bar cutting the stator drives the rotor.
PMSM Motor: The permanent magnets are embedded in the rotor magnetic poles, and are driven to rotate by the rotating magnetic field generated in the stator according to the principle of magnetic poles of the same phase attracting different repulsion.
02. Efficiency
Asynchronous motors: Need to absorb current from the grid excitation, resulting in a certain amount of energy loss, motor reactive current, and low power factor.
PMSM Motor: The magnetic field is provided by permanent magnets, the rotor does not need exciting current, and the motor efficiency is improved.
03. Volume And Weight
The use of high-performance permanent magnet materials makes the air gap magnetic field of permanent magnet synchronous motors larger than that of asynchronous motors. The size and weight are reduced compared to asynchronous motors. It will be one or two frame sizes lower than asynchronous motors.
04. Motor Starting Current
Asynchronous motor: It is directly started by power frequency electricity, and the starting current is large, which can reach 5 to 7 times the rated current, which has a great impact on the power grid in an instant. The large starting current causes the leakage resistance voltage drop of the stator winding to increase, and the starting torque is small so heavy-duty starting cannot be achieved. Even if the inverter is used, it can only start within the rated output current range.
PMSM Motor: It is driven by a dedicated controller, which lacks the rated output requirements of the reducer. The actual starting current is small, the current is gradually increased according to the load, and the starting torque is large.
05. Power Factor
Asynchronous motors have a low power factor, they must absorb a large amount of reactive current from the power grid, the large starting current of asynchronous motors will cause a short-term impact on the power grid, and long-term use will cause certain damage to the power grid equipment and transformers. It is necessary to add power compensation units and perform reactive power compensation to ensure the quality of the power grid and increase the cost of equipment use.
There is no induced current in the rotor of the permanent magnet synchronous motor, and the power factor of the motor is high, which improves the quality factor of the power grid and eliminates the need to install a compensator.
06. Maintenance
Asynchronous motor + reducer structure will generate vibration, heat, high failure rate, large lubricant consumption, and high manual maintenance cost; it will cause certain downtime losses.
The three-phase Permanent magnet synchronous motor drives the equipment directly. Because the reducer is eliminated, the motor output speed is low, mechanical noise is low, mechanical vibration is small, and the failure rate is low. The entire drive system is almost maintenance-free.
The three-phase Permanent magnet synchronous motor drives the equipment directly. Because the reducer is eliminated, the motor output speed is low, mechanical noise is low, mechanical vibration is small, and the failure rate is low. The entire drive system is almost maintenance-free.