20kw 37kw 55kw TYB Rare Earth AC Synchronous PM Motor For Fans And Pumps

Product Details

Place of Origin: China

Brand Name: ENNENG

Certification: CE,UL

Model Number: TYB

Payment & Shipping Terms

Minimum Order Quantity: 1 set

Price: USD 500-5000/set

Packaging Details: seaworthy packing

Delivery Time: 15-120 days

Payment Terms: L/C, T/T

Supply Ability: 20000 sets/year

Get Best Price
Highlight:

AC Synchronous PM Motor

,

TYB Rare Earth PM Motor

,

55kw AC PM Motor

Name:
20kw 37kw 55kw Rare Earth Material AC Permanent Magnet Synchronous Motor
Current:
AC
Material:
Rare Earth NdFeB
Power Range:
5.5-3000kw
Installation:
IMB3 IMB5 IMB35
Phase:
3 Phase
Voltage:
380v, 660v, 1140v, 3300v, 6kv, 10kv
Housing:
Cast Iron
Name:
20kw 37kw 55kw Rare Earth Material AC Permanent Magnet Synchronous Motor
Current:
AC
Material:
Rare Earth NdFeB
Power Range:
5.5-3000kw
Installation:
IMB3 IMB5 IMB35
Phase:
3 Phase
Voltage:
380v, 660v, 1140v, 3300v, 6kv, 10kv
Housing:
Cast Iron
20kw 37kw 55kw TYB Rare Earth AC Synchronous PM Motor For Fans And Pumps

20kw 37kw 55kw TYB Rare Earth Material AC Synchronous Permanent Magnet Motor For Fans And Pumps

 

Product Parameters


Energy efficiency standards

comply with GB30253-1 grade

Work mode
S1
Installation dimensions
comply with IEC standard

Control mode

variable frequency vector control
Power range 7.5 〜160kW
Governing range

constant torque: 0〜3000r/min
Cooling way
IC411 (fan cooling)

Field Weakening: 3000 〜3600r/min
Power range 7.5 〜250kW
Governing range

constant torque: 0〜1500r/min
Cooling way
IC416 (independent axial flow fan)
Field Weakening: 1500 〜1800r/min
Insulation class F
Optional parts

Encoder, spiral transformer, PTC, PT100
Protection grade
IP54 (IP23 customizabe)

Wiring type

junction box (aviation plug can be customized as per requirement)
installation IMB3 IMB5 IMB35
Service factor

Standard 1, 2 (customized as per requirement)

Required environment

below 1000m altitude

temperature -15〜45°C

relative humidity below 90%

 

Model Type

 


Model

Power
(kW)

rated volt (V)

rated current
(A)

frequency
(Hz)

No. of poles

rated speed
(r/min )

rated torque
(N • m )

efficiency
(%)

weight
(kg)
TYB-132M1-6 7.5 380 14.5 75 6 1500 47.8 92.6 61
TYB-132M2-6 11 380 21 75 6 1500 70 93.6 73
TYB-160M1-6 11 380 210 75 6 1500 70 93.6 108
TYB-160M2-6 15 380 28.5 75 6 1500 95.B 94 124
TYB-160L1-6 18.5 380 35.1 75 6 1500 117.8 94.3 132
TYB-160L2-6 22 380 415 75 6 1500 140 94.7 141
TYB-225S1-8 30 B80 56.4 100 8 1500 191 95 261
TYB-225S2-8 37 380 69.4 100 8 1500 235.6 953 274
TYB-225M1-8 45 380 84.1 100 8 1500 286.5 95.6 284
TYB-225M2-8 55 380 102.6 100 8 1500 350 95.8 297
TYB-225MX-8 75 380 141.7 100 8 1500 477.5 96 336
TYB-280S-8 90 380 169.7 100 8 1500 573 96.2 484
TYB-280M1-8 110 380 207 100 8 1500 700 96.4 512
TYB-280M2-8 132 380 248.1 100 8 1500 840 96.5 555
TYB-315S-8 160 380 300.8 100 8 1500 1018.7 96.5 756
TYB-315M-8 200 380 375.6 100 8 1500 1273.3 96.6 850
TYB-315L1-8 220 380 413.2 100 8 1500 14007 96.6 910
TYB-315L2-8 250 380 469.1 100 8 1500 15917 96.7 1055
                   

Model

Power
(kW)

rated volt (V)

rated current
(A)

frequency
(Hz)

No. of poles

rated speed
(r/min )

rated torque
(N • m )

efficiency
(%)

weight
(kg)
TYB-132M1-4 7.5 380 14.6 100 4 3000 23.9 92.1 71
TYB-132M2-4 11 380 21.1 100 4 3000 35 93 87
TYB-160M1-4 15 380 28.7 100 4 3000 47.8 93.4 118
TYB-160M2-4 22 380 41.7 100 4 3000 70 94.4 126
TYB-180M1-4 30 380 56.7 100 4 3000 95.5 94.5 175
TYB-180M2-4 37 380 69.8 100 4 3000 117.8 94.8 186
TYB-200L1-4 45 380 84.6 100 4 3000 142.3 95.1 241
TYB-200L2-4 55 380 103.1 100 4 3000 175 95.4 259
TYB-225M-4 75 380 141 100 4 3000 238.8 95.6 388
TYB-225MX-4 90 380 168.7 100 4 3000 286.5 95.8 421
TYB-280S1-8 110 380 205.7 200 8 3000 350 96 486
TYB-280S2-8 132 380 246.9 200 8 3000 420 96 534
TYB-280M-8 160 380 398.6 200 8 3000 509 96.2 698

Advantages:

 

1. Small and Light

Volume ratio: average 35% smaller, weight ratio: average 40% lighter

Motor Frame Size Is decreased by 1 ~ 3, compared with the asynchronous motor.

It can realize mechanical miniaturization to save space.

 

2. High Power Factor

Reduce the capacity of power-receiving equipment.

There is no doubt of high efficiency. Compared with asynchronous motors, it may reduce the current volume of equipment due to the high power factor.

 

3. High Efficiency•Energy Saving

Motor efficiency is equal to IE3 (High efficiency: above GB2 level)

Note: IE3 is the efficiency grade specified in IEC 60034-30.

 

Detailed pictures
 
20kw 37kw 55kw TYB Rare Earth AC Synchronous PM Motor For Fans And Pumps 0
 
The cases for reference (PM Motor for water pump):
 
20kw 37kw 55kw TYB Rare Earth AC Synchronous PM Motor For Fans And Pumps 1
20kw 37kw 55kw TYB Rare Earth AC Synchronous PM Motor For Fans And Pumps 2
 
Installation Size:
20kw 37kw 55kw TYB Rare Earth AC Synchronous PM Motor For Fans And Pumps 3

 

Maintenance and repair of electric motors:

 

1. The operating environment should always be kept dry, the surface of the motor should be kept clean, and the air inlet should not be obstructed by dust, fibers, etc.

 

2. When a protection alarm occurs, the cause of the failure should be found out, and the operation can only be put into operation after the failure is eliminated.

 

3. When the machine is stopped for inspection, the operation can only be carried out after the motor has completely stopped.

 

4. In order to ensure good lubrication of the motor during operation, the motor should run for about 4000 hours, that is, the grease should be supplemented or replaced (the closed bearing does not need to be replaced during the service life). When the bearing is found to be overheated or the grease deteriorates during operation, The grease should be replaced in time. When replacing the grease, remove the old grease and clean the oil grooves of the bearings and bearing caps with gasoline. For motors with a speed of 1500r/min and below, refill the bearing grease type for medium and small motors bearing grease No. 2, and fill the inner and outer rings of the bearing About two-thirds of the gap between the bearings; the motor speed of 2500r/min and above is filled with bearing grease type HTHS, which fills about one-half of the gap between the inner and outer rings of the bearing.

 

5. When the life of the bearing is over, the vibration and noise of the motor will increase obviously. Check that the radial clearance of the bearing reaches the value in the table below, and the bearing should be replaced.

 

Storage and transportation of electric motors:

 

1. The motor should be kept dry during storage to avoid sudden changes in ambient temperature.

 

2. The storage of the motor should not be too high to avoid damage to the lower motor.

 

3. The motor should be prevented from tipping or inverting during storage and transportation.