Product Details
Place of Origin: China
Brand Name: ENNENG
Certification: CE,UL
Model Number: PMM
Payment & Shipping Terms
Minimum Order Quantity: 1 set
Price: USD 500-5000/set
Packaging Details: seaworthy packing
Delivery Time: 15-120 days
Payment Terms: L/C, T/T
Supply Ability: 20000 sets/year
Name: |
220v Permanent Magnet Universal Motor |
Current: |
AC |
Material: |
Rare Earth NdFeB |
Installation: |
IMB3 IMB5 IMB35 |
Phase: |
3 Phase |
Poles: |
2,4,6,8,10 |
Power Range: |
5.5-3000kw |
Voltage: |
380v, 660v, 1140v, 3300v, 6kv, 10kv |
Frame Size: |
From H112 To H450 |
Application: |
Rotary Screw Air Compressor |
Name: |
220v Permanent Magnet Universal Motor |
Current: |
AC |
Material: |
Rare Earth NdFeB |
Installation: |
IMB3 IMB5 IMB35 |
Phase: |
3 Phase |
Poles: |
2,4,6,8,10 |
Power Range: |
5.5-3000kw |
Voltage: |
380v, 660v, 1140v, 3300v, 6kv, 10kv |
Frame Size: |
From H112 To H450 |
Application: |
Rotary Screw Air Compressor |
Product Description:
In an air compressor, a permanent magnet motor is commonly used to drive the compressor pump. The motor's rotational motion is transmitted to the pump, which then compresses the air and delivers it at high pressure.
The use of a permanent magnet motor in an air compressor can result in improved energy efficiency, reduced operating costs, and increased overall performance. These motors are often found in industrial and commercial air compressors, where dependable and efficient operation is crucial.
Architectural Feature:
Frame size | 132 | 160 | 180 | 200 | 225 | 250M/L | 280M/L | ||||
Mechanical Properties | |||||||||||
Frame/End shield /Terminal boxes |
Material | Cast Iron | |||||||||
Mounting | B3/B35 | ||||||||||
IP Grade | IP23 | ||||||||||
Cooling Method | IC01(ODP) | ||||||||||
Earth | Inside the wiring cover and the machine base | ||||||||||
Bearing | Dust cover/clearance | ZZ/C3 | /C3 | ||||||||
Bearing fix | DE fix, NDE with Wave spring washer | ||||||||||
DE fix bearings |
3000rpm | 6308 | 6309 | 6312 | 6312 | 6313 | 6314/6318 | 6314/6318 | |||
1500rpm | 6308 | 6309 | 6312 | 6312 | 6313 | 6318/6318 | 6318/6318 | ||||
NDE fix bearings |
3000rpm | 6308 | 6309 | 6312 | 6312 | 6313 | 6314/6316 | 6314/6316 | |||
1500rpm | 6308 | 6309 | 6312 | 6312 | 6313 | 6316/6316 | 6316/6316 | ||||
Lubrication |
Material | ESSO UNIREX N2 | |||||||||
Oil pipe | / | End shield oiling device | pipe | ||||||||
plug | With rubber blind cover for transportation and storage | ||||||||||
Shaft | Material | Steel45# | |||||||||
B type | |||||||||||
vibration limit (mm/s) |
1.6 | 2.2 | |||||||||
Balance | 1/2 key G2.5 grade | ||||||||||
Nameplate |
Material |
Aluminum alloy | |||||||||
Electrical performance | |||||||||||
Voltage | 380/400V(or440/460V)three terminals | ||||||||||
Winding |
Material | high purity copper | |||||||||
Dipping method |
VPI and drying | ||||||||||
Insulation grade | 155(F) | ||||||||||
Service Factor | 1.0/1.2/1.3 | ||||||||||
stator and rotor lamination |
silicon steel | ||||||||||
permanent magnet | NdFeB |
B3/B35 size | Universal size | ||||||||||||||
Frame size | A | AA | AB | B | BB | HA | H | K | C | AC | AD | BS | KK | L | |
3000rpm | 1500rpm | ||||||||||||||
132S | 216 | 63 | 270 | 140 | 190 | 20 | 132 | 12 | 89 | 275 | 213 | 0 | M33 | 508 | |
132M | 178 | 230 | 546 | ||||||||||||
160M | 254 | 73 | 320 | 210 | 274 | 20 | 160 | 15 | 108 | 330 | 260 | 65 | M33 | 659 | |
160L | 254 | 318 | 87 | 714 | |||||||||||
180M | 279 | 73 | 355 | 241 | 315 | 22 | 180 | 15 | 121 | 380 | 280 | 67 | M48 | 738 | |
180L | 279 | 355 | 86 | 778 | |||||||||||
200L | 318 | 73 | 395 | 305 | 375 | 25 | 200 | 19 | 133 | 400 | 305 | 86 | M48 | 820 | |
225S | 356 | 83 | 435 | 286 | 375 | 28 | 225 | 19 | 149 | 470 | 335 | 87 | M48 | 820 | |
225M | 311 | 400 | 100 | 845 | |||||||||||
280S | 457 | 93 | 550 | 368 | 490 | 35 | 280 | 24 | 190 | 547 | 400 | 158 | M64 | 985 | |
280M | 419 | 540 | 184 | 1035 | |||||||||||
315S | 508 | 120 | 635 | 406 | 575 | 45 | 315 | 28 | 216 | 645 | 530 | 162 | M75 | 1185 | 1215 |
315M | 457 | 685 | 188 | 1295 | 1325 |
Universal size | B35/B5/V1size | ||||||||||||||||
Frame size | D | E/DE | F | G | GD | N | M | P | S | T | R | LA | |||||
3000 rpm |
1500 rpm |
3000 rpm |
1500 rpm |
3000 rpm |
1500 rpm |
3000 rpm |
1500 rpm |
3000 rpm |
1500 rpm |
||||||||
132S | 38k6 | 80/70 | 10 | 33 | 8 | 230j6 | 265 | 300 | 15 | 4 | 0 | 14 | |||||
132M | |||||||||||||||||
160M | 42k6 | 110/80 | 12 | 37 | 8 | 250j6 | 300 | 350 | 19 | 5 | 0 | 15 | |||||
160L | |||||||||||||||||
180M | 48k6 | 110/80 | 14 | 42.5 | 9 | 250j6 | 300 | 350 | 19 | 5 | 0 | 15 | |||||
180L | |||||||||||||||||
200L | 55m6 | 110/80 | 16 | 49 | 10 | 300j6 | 350 | 400 | 19 | 5 | 0 | 17 | |||||
225S | 60m6 | 140/100 | 16 | 18 | 49 | 53 | 10 | 11 | 350j6 | 400 | 450 | 19 | 5 | 0 | 20 | ||
225M | |||||||||||||||||
280S | 65m6 | 75m6 | 140/100 | 18 | 20 | 58 | 67.5 | 11 | 12 | 450j6 | 500 | 550 | 19 | 5 | 0 | 22 | |
280M | |||||||||||||||||
315S | 65m6 | 80m6 | 140/100 | 170/140 | 18 | 22 | 58 | 71 | 11 | 14 | 550 | 600 | 660 | 24 | 6 | 0 | 25 |
315M |
1. Energy efficiency: Permanent magnet motors are more energy-efficient compared to traditional induction motors. They have a higher power factor and lower losses, resulting in reduced energy consumption and lower operating costs.
2. Compact size: Permanent magnet motors are smaller and lighter compared to induction motors of the same power rating. This makes them ideal for applications where space is limited, such as in portable air compressors or in installations with space constraints.
3. Improved performance: Permanent magnet motors offer better torque and speed control, allowing for precise and efficient operation. They have a higher starting torque and faster response time, resulting in quicker acceleration and deceleration of the air compressor.
4. Enhanced reliability: Permanent magnet motors have a simpler design with fewer moving parts, reducing the chances of mechanical failure. They also have a longer service life and require less maintenance compared to induction motors, leading to increased reliability and reduced downtime.
5. Increased power density: Permanent magnet motors have a higher power density, meaning they can deliver more power in a smaller package. This allows for the design of more compact and lightweight air compressors without compromising on performance.
6. Variable speed operation: Permanent magnet motors can be easily controlled for variable speed operation, allowing the air compressor to adjust its output based on demand. This helps in reducing energy wastage and optimizing the efficiency of the air compressor.
Overall, the use of permanent magnet motors in air compressors offers significant advantages in terms of energy efficiency, compactness, performance, reliability, and flexibility. These benefits make them a preferred choice for various air compressor applications.